TROUBLESHOOTING
16
TROUBLESHOOTING
SYMPTOM POSSIBLE PROBLEMS SERVICE
Returning/Purging Stage of Operation
If the TrakFast tool will not operate after following the above service directions,
return the tool to an Ramset Distributor Sales Representative for service.
800-241-5640
www.ramset.com
— Tool operated and
drove fastener, but
piston did not return
to up position.
— Combustion Chamber
does not drop after tool
cycles.
— Built-up dirt and debris
on Piston or in Nose
bore.
— Mushrooming of
Piston Tip.
— Exhaust ports on the
Sleeve are dirty or
clogged.
— Tool (Sleeve) or
O-Rings are dirty.
— Work Contacting
Element is bent,
or tool is dirty.
— Clean Piston and Nose bore with safety
solvent.
— Contact Ramset Distributor Sales
Representative for service.
— Return tool to Authorized Ramset Distributor
Sales Representative for service.
— Clean tool per Cleaning Procedure.
— Clean tool or replace Work Contacting
Element as required.
Comentários a estes Manuais